FCPK 2-8 CONVENTIONAL CONTROL PANELS
The FCPK 2-8 Fire Alarm Control Panel is a flexible, expandable conventional system available from 2 to 8 zones.
The panel is designed to be aesthetically pleasing with a contrasting membrane facia incorporating tactile controls with a key switch override and matches the other panels in the range. The FCPK 2-8 control panel can greatly reduce wiring installation costs by utilising its unique 2-Wire zone configuration. This allows sounders to be wired on the same trigger zone circuit, therefore eliminating the need for the sounder circuitry wiring.
LITERATURE
FEATURES
- Available from 2 to 8 zone
- Designed to comply with BS5839 pt 4 1988 and EN54 pts 2 & 4
- Programmable microprocessor based system
- Enclosure is manufactured from high quality steel, available with optional flush bezel.
- Has built in power supply and charger unit, accepts 2 No. 12 volt 6 Ampere hour batteries
- One man commissioning – allows trigger devices and sounders to be automatically reset after alarm initiation.
- Zone configuration allows for conventional or Sav-Wire working per zone.
- Zone Isolation – allowing individual zones to be disabled for maintenance or other work to be carried out. During zone isolation, the zone sounders are still active.
- Zone Alarm isolation – allowing the zone alarms to be disabled whilst the detection for that zone is still active.
- De-latch facility to allow non-latching of individual zones with or without alarms.
- A maximum of 7 Active AND 7 passive repeaters may be connected to the panel
SPECIFICATION | FCPK 2-8 CONTROL PANELS |
---|---|
Panel Dimensions | 385mm wide, 310mm high, 95mm deep |
Operating Voltage | 230V 50Hz AC (UK) – other voltages available |
Power Supply | 3 Amp maximum output |
Sounder Output | 2 short and open circuit protected monitored outputs 500 mA output per conventional sounder circuit. Total 1.6A max |
Auxiliary Relay | 2 x Volt free changeover contacts 1 Amp 24V max. per relay |
Detector Circuit | Sav-Wire to operate with Sav-Wire type detector bases |
Maximum Devices | 20 per zone |
2-Wire alarm zone | Optional 350 mA max alarm load per zone |
Devices Supported | All Apollo, Hochiki, Nittan and most other manufacturers detectors. Please check for details |
Quiescent Current | 65mA (2 Zone), 93mA (8 Zone) |
Display | 8 LED zone Fire indicators, 8 LED zone Fault indicators, 1 LED common Fire indicators |
Keyboard | Membrane click action tactile 11 keys |
Fascia | Contrasting grey colour as standard, other options available |
Number of zones | 2 – 8 as standard |
Additional Equipment | 2 way sounder expansion card, 4 wire repeater panel, Auxiliary Dual Relay PCB’s, Multi-function Timer PCB, Modem driver PCB’s for connection to the BT network, Line I/O unit |
Auxiliary Outputs | Common Fire, Common Fault, 24v supply |
Auxiliary Inputs | Ring Bells (Class Change) (COV), Reset, Silence Alarms (SAL) |